• Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive
  • Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive
  • Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive
  • Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive
  • Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive
  • Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive

Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive

After-sales Service: Supply Parts
Warranty: 1 Year
Type: Basic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Samples:
US$ 10000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Other

Basic Info.

Model NO.
GF2 -550KVA
Output Type
AC Three Phase
Speed
Low Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Nantong Engine Generator
550kVA
Transport Package
by steel frame with plywood case
Specification
400KW
Trademark
hot-stuff
Origin
Fujian
Production Capacity
1000pcs/year

Product Description

Emergency Power Big Generator, Use Weichai, Nantong and So on to DriveAs a manufacturer, we specialize in water cooled generator from 8kw to 500kw. Have about 5 year experience. Punctual delivery, good quality, competitive price.
MODEL GF2-550KVA
Powered by WEICHAI/YUCHAI/NANTONG Engine
Prime Power (50HZ/60HZ) 400KW/500KVA
Standby Power (50HZ/60HZ) 440kw/550KVA
Power Factor 0.8   Lagging
Phase Wires 3-phases 4-Wires
Start Model Electric
Fuel Consumption 97L/h at 100% Load
Protection Low oil-pressure, High water temperature,
Over-speed, Over-current
Engine Model KTA19-G4
Cylinders 6
Cylinder Arrangement L
Bore x Stroke(mm) 159X 159
Compression Ratio 13.9: 1
Speed 1500rpm/1800rpm
Cooling Method Water - cooled
Starting Method 24V DC electrical start
Full Load Diesel Consumption (L/H) 17
Engine Displacement (L) 19
Inspiration  (L) Turbocharged Intercooled
Lube Volume  (L) 50
Coolant Volume  (L) 95
Noise (Db) ≤ 103
Governor Type Electric Governing
Alternator Model Stanford  HCI544C
Alternator Power 500KVA
Voltage 220/380 V
Protection IP23
Voltage Regulation ± 4%
Insulation Class H
Voltage Control AVR
Net Weigh (KGS) 4700
Dimensions (L x W x H) mm 3500*1200*1900
Optional  
  ATS (auto transfer switch)
  BatteryCharger
  Base Fuel Tank (for open type)
 Emergency Power Big Generator, Use Weichai, Nantong and So on to Drive

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now